📘 Lecture 13 — (Applications of Loop Analysis)
📖 Overview: This lecture demonstrates how to apply Kirchhoff's Voltage Law (KVL) to solve for unknown voltages between two points that are not physically close in a circuit. It teaches students how to use imaginary arrow notation and multiple closed paths to determine voltages like (V_{AE}) and (V_{EC}), and how to systematically write KVL equations for circuits with multiple loops.
🗂️ Topics Covered
This lecture covers three worked examples: calculating voltage (V_{AE}) and (V_{EC}) using multiple closed paths (AEFA, ABCDEA, CDEC, CEABC, CEFABC); writing KVL equations for a two-loop circuit (loops ABCA and BDCB) with resistors and a voltage source; and calculating voltage (V_{bd}) across an open branch using closed paths abda and bcdb.
📝 Lecture Summary
Example: Calculate the voltages (V_{AE}) and (V_{EC})
To find voltages between points that are not physically close, we draw imaginary arrows across the points A, E, and C. The circuit is redrawn with these arrows.
Our approach is to apply KVL in a closed path that includes the unknown voltage. For (V_{AE}), we can use either path AEFA or path ABCDEA.
For path AEFA: [ V_{AE} + 10 - 24 = 0 ] [ V_{AE} = 14 \text{ volts} ]
For path ABCDEA: [ 16 - 12 + 4 + 6 - V_{AE} = 0 ] [ V_{AE} = 14 \text{ volts} ]
Solving both loops gives (V_{AE} = 14) volts.
To calculate (V_{EC}), we can use paths CDEC, CEFABC, or CEABC (since (V_{AE}) is now known).
For loop CDEC: [ 4 + 6 + V_{EC} = 0 ] [ V_{EC} = -10 \text{ volts} ]
For loop CEABC: [ -V_{EC} + V_{EA} + 16 - 12 = 0 ] where (V_{EA} = -V_{AE} = -14) volts [ -V_{EC} - 14 + 16 - 12 = 0 ] [ V_{EC} = -10 \text{ volts} ]
For loop CEFABC: [ -V_{EC} + 10 - 24 + 16 - 12 = 0 ] [ V_{EC} = -10 \text{ volts} ]
Each of the three paths gives the same result: (V_{EC} = -10) volts.
💡 Why this matters: When a voltage is not directly measurable between two distant points in a circuit, you can still find it by applying KVL around a closed loop that contains the unknown voltage.
🔑 Definition — Imaginary Arrow Notation: A method used to represent a voltage between two points that are not physically adjacent in a circuit, allowing KVL to be applied in a closed loop. 📐 Formula: (V_{AE} + V_{EA} = 0) → The voltage from A to E is the negative of the voltage from E to A. 📌 Example: In the path AEFA, the loop includes (V_{AE}), a 10V source, and a 24V source. Applying KVL: (V_{AE} + 10 - 24 = 0) gives (V_{AE} = 14V).
Example: Write KVL equations for the given circuit
The circuit has two loops: left loop ABCA and right loop BDCB.
KVL equation for left hand loop ABCA: [ V_{R1} + V_{R2} - V_s = 0 ]
KVL equation for right hand loop BDCB: [ 20V_{R1} + V_{R3} - V_{R2} = 0 ]
Note: The notation (20V_{R1}) suggests a dependent source or a scaling factor applied to the voltage across R1.
🔑 Definition — KVL (Kirchhoff's Voltage Law): The sum of all voltages around any closed loop in a circuit must equal zero. 📐 Formula: (\sum V = 0) around a closed loop → The algebraic sum of voltage rises and drops must be zero. 📌 Example: In loop ABCA, the voltage source (V_s) is a rise, while (V_{R1}) and (V_{R2}) are drops, giving (V_{R1} + V_{R2} - V_s = 0).
Example: Calculate the voltage (V_{bd})
We want (V_{bd}) between points b and d. Since there is no direct closed path between b and d, we redraw the circuit to show the open branch.
We consider two closed paths: abda and bcdb.
KVL equation for path abda: [ 2 + V_{bd} - 9 = 0 ] [ V_{bd} = 7 \text{ volts} ]
KVL equation for path bcdb: [ 4 + 3 - V_{bd} = 0 ] [ V_{bd} = 7 \text{ volts} ]
Both paths give the same result: (V_{bd} = 7) volts.
💡 Why this matters: Even when two points are in an open branch with no component connecting them directly, you can still find the voltage between them by applying KVL to a closed loop that goes around through other components.
🔑 Definition — Open Branch Voltage: The voltage across two points that are not connected by a direct component path can be found using KVL in a closed loop that includes those points. 📐 Formula: (V_{bd} = V_{ba} + V_{ad}) → Voltage across an open branch equals the sum of voltages along any closed path connecting the points. 📌 Example: In path abda, starting at point a, we have a 2V rise to b, then unknown (V_{bd}) to d (in the same direction as the loop), then a 9V drop back to a. KVL gives (2 + V_{bd} - 9 = 0), so (V_{bd} = 7V).
⭐ Key Takeaways
The most critical skill from this lecture is the ability to find a voltage between any two points in a circuit by applying KVL to a closed loop that contains those points as nodes, even if they are not physically adjacent or directly connected. When a voltage appears with a negative sign in the solution, it simply means the actual polarity is opposite to the assumed arrow direction. Students must be comfortable using multiple different closed paths to verify the same unknown voltage, as all paths must yield the same result if KVL is correctly applied. The concept of imaginary arrow notation is essential for handling voltages between distant nodes in complex circuits.
🧠 Quick Revision Questions
- For the first example, what value does each of the three paths give for (V_{EC})?
- How do you define an "imaginary arrow" when measuring voltage between two distant points?
- In the second example, what is the KVL equation for the left hand loop ABCA?
- In the third example, what are the two closed paths used to find (V_{bd})?
- If (V_{AE} = 14) volts, what is (V_{EA})?
📘 Lecture 14 — Applications of Loop Analysis
📖 Overview: This lecture demonstrates practical applications of loop (mesh) analysis and nodal analysis for solving complex circuits. It shows how to calculate power dissipation in resistors and find unknown voltages across specific network points using multiple analysis techniques.
🗂️ Topics Covered
The lecture covers three worked examples: finding power dissipated by a 3Ω resistor using both mesh and nodal analysis, calculating voltage Vcf across a network using KVL along different paths, and determining voltages Vad and Vce in a network by redrawing the circuit and applying KVL to multiple paths.
📝 Lecture Summary
Example: Find the power dissipated by 3Ω resistance.
The circuit has two meshes with currents I₁ and I₂ both flowing clockwise. The current through the 3Ω resistor is I₃ = I₁ - I₂.
For mesh 1:
- The voltage rises across the -2V source: -(-2) = +2V
- Voltage across 5Ω: V₅ = 5I₁
- Voltage across 3Ω: Vₓ = 3(I₁ - I₂)
- KVL: 2 + 5I₁ + 3(I₁ - I₂) = 0
- Equation (A): 8I₁ - 3I₂ = -2
For mesh 2:
- Voltage across 3Ω: 3(I₂ - I₁)
- Voltage across 2Ω: 2I₂
- Voltage across 3V source (rising): +3
- Equation (B): -3I₁ + 5I₂ = -3
Solving equations (A) and (B):
- I₁ = -612.9 mA
- I₂ = -967.7 mA
- I₃ = I₁ - I₂ = 354.8 mA
📌 Example: Power dissipated in 3Ω resistor = 3 × (0.3548)² = 377.7 mW
Note: The direction of subtraction (I₁ - I₂ or I₂ - I₁) doesn't matter due to the square term.
Verification using Nodal Analysis:
- Node voltage V at the top of 3Ω resistor
- Three currents leaving the node: through 5Ω toward -2V, through 3Ω to ground, through 2Ω toward +3V
- Equation: 0 = (V - (-2))/5 + V/3 + (V - 3)/2
- Solving: V = 1.065V
- 💡 Why this matters: Confirms mesh analysis is correct.
- Power₃Ω = V²/3 = (1.065)²/3 = 378.1 mW (slight difference due to rounding)
🔑 Definition — Mesh Analysis: A circuit analysis method that assigns loop currents to each independent mesh and applies KVL to solve for unknown currents.
📐 Formula: Power dissipated = I²R = V²/R → where I is current through the resistor or V is voltage across it.
Example: Calculate the voltage Vcf in the network.
The network is redrawn to show clear paths between points c and f.
Path abcfa (upper path):
- Voltage drops: -4V (across left element) + 9V (source rise) + Vcf - 6V = 0
- Vcf = 1 volt — Equation (A)
Path cdefc (lower path):
- Voltage drops: -5V - 6V - 12V + Vfc = 0
- Vfc = -1 volt — Equation (B)
🔑 Definition — Vcf and Vfc: Vcf is the voltage at point c with respect to point f; Vfc is the voltage at f with respect to c. They are related by Vcf = -Vfc.
From equation (B): Since Vcf = -Vfc, we get Vcf = -(-1) = 1 volt
💡 Why this matters: The same voltage can be found using two different paths, validating Kirchhoff's Voltage Law and providing redundancy in circuit analysis.
Example: Calculate the voltage Vad and Vce in the network.
The circuit is redrawn because there is no physical closed path between these points.
For Vad: Two paths exist where Vad is the only unknown:
Path adea:
- Vad - 1V - 4Vx = 0
- Given Vx = 2V
- Vad - 1 - 8 = 0
- Vad = 9 volts
Path adcba (for verification):
- Vad - 12 + 2 + 1 = 0
- Vad = 9 volts (confirms the calculation)
💡 Why this matters: When circuits lack direct connections, redrawing them into equivalent topological layouts helps identify valid KVL paths.
⭐ Key Takeaways
The lecture demonstrates three critical skills: solving simultaneous mesh equations with opposite-direction currents to find individual branch currents; verifying mesh analysis results using nodal analysis for cross-validation; and finding voltages between arbitrary points in a network by choosing appropriate KVL paths. The sign convention for currents (I₁ - I₂ vs I₂ - I₁) determines the direction but not the magnitude of power calculation. Multiple paths between two points should yield the same voltage, providing a built-in verification method. Circuit redrawing is essential when no direct closed path exists between measurement points.
🧠 Quick Revision Questions
- In the first example, why does the direction of subtraction (I₁-I₂ or I₂-I₁) not matter when calculating power?
- What are the two mesh equations derived for the 3Ω resistor power example, and what do they represent?
- How does nodal analysis confirm the results from mesh analysis in the first example?
- Why must Vcf equal -Vfc, and how does this relationship help verify calculations?
- In the third example, what are the two paths used to calculate Vad, and why do both give the same answer?
📘 Lecture 15 — Applications of Loop Analysis
📖 Overview: This lecture demonstrates practical applications of loop analysis (KVL) to calculate unknown voltages across various points in circuits. The examples show how to systematically apply Kirchhoff's Voltage Law to different paths in a circuit, even when no physical closed path exists between two points, and how to use mesh current analysis to find specific voltages.
🗂️ Topics Covered
The lecture covers three detailed examples of applying loop analysis techniques. The first example calculates voltages Vad, Vac, and Vbd in a simple circuit with multiple voltage sources. The second example extends the technique to find Vac and Vdb across different branches. The third example demonstrates mesh current analysis with a current source to calculate V0 across a resistor combination.
📝 Lecture Summary
Example: Calculate the voltages V_ad, V_ac and V_bd.
This example demonstrates calculating voltages between points that may not have a direct physical path between them. The circuit contains voltage sources of 12V, 4V, 6V, and 2V arranged in a rectangular configuration.
To find V_ad, we observe there is only a voltage source between points a and d, so V_ad = 12 volts directly.
For V_ac, there is no physical closed path between points a and c. We consider two possible closed paths:
- Path acba: KVL equation → V_ac - 4 - 6 = 0 → V_ac = 10 Volts
- Path acda: KVL equation → V_ac + 2 - 12 = 0 → V_ac = 10 Volts
Both paths give the same result, verifying the calculation.
🔑 Definition — V_db: The voltage from point d to point b, which is the negative of V_bd (V_db = -V_bd).
💡 Why this matters: When calculating voltages between arbitrary points in a circuit, we can use any closed path that includes both points, as long as we maintain consistent sign conventions.
Example: Calculate the voltages V_ac and V_db.
This example extends the technique to a more complex circuit with voltage sources of 10V, 12V, 6V, and 8V arranged in a rectangular configuration with a diagonal branch.
For V_ac, the two paths used are:
- Path acda: V_ac + 8 - 12 = 0 → V_ac = 4 volts
- Path acba: V_ac + 6 - 10 = 0 → V_ac = 4 volts
For V_bd, the two paths are:
- Path bdcb: V_bd - 8 + 6 = 0 → V_bd = 2 volts, therefore V_db = -2 volts
- Path bdab: V_bd - 12 + 10 = 0 → V_bd = 2 volts, therefore V_db = -2 volts
📐 Formula — Voltage sign convention: When traversing a voltage source from negative to positive terminal, add its voltage; when going from positive to negative, subtract its voltage.
📌 Example: In path bdcb: Starting at b, go to d (unknown V_bd), then to c (-8V because we encounter negative terminal first), then to b (+6V because we encounter positive terminal first). Thus: V_bd - 8 + 6 = 0 → V_bd = 2V.
Example: Calculate the voltage V_0.
This example introduces mesh current analysis combined with a practical application to find the voltage V0 across specific components.
The circuit contains:
- A 12V voltage source in series with a 3kΩ resistor
- A 6kΩ resistor between mesh 1 and mesh 2
- A 2mA current source in mesh 2
- A 2kΩ resistor in mesh 2
Given I₂ = 2 mA (from the current source), we write the KVL equation for mesh 1:
3k(I₁) + 6k(I₁ - I₂) - 12 = 0
9k(I₁) - 6k(I₂) = 12
9k(I₁) - 6k(2mA) = 12
9k(I₁) - 12 = 12
9k(I₁) = 24
I₁ = 8/3 mA
Voltage across 6kΩ resistor: V = 6k(I₁ - I₂) = 6k(8/3 - 2) = 6k(8/3 - 6/3) = 6k(2/3) = 4 volts
Voltage across 2kΩ resistor: V₂ₖ = 2k × I₂ = 2k × 2mA = 4 volts
V₀ = V₆ₖ - V₂ₖ = 4 - 4 = 0 volts
📐 Formula — Mesh current: For a resistor shared between two meshes, the voltage drop = R × (I_mesh1 - I_mesh2), where the direction is determined by the mesh under analysis.
🔑 Definition — Supermesh: When a current source is present between two meshes, we can combine those meshes into a supermesh to avoid having to write KVL through the current source. However, in this example, the current source is on the outer edge of mesh 2, so it directly determines I₂.
💡 Why this matters: The result V₀ = 0 volts shows that the voltage drops across the 6kΩ and 2kΩ resistors exactly cancel each other, demonstrating that different circuit paths can produce equal and opposite voltages.
⭐ Key Takeaways
The most critical concepts to remember are: (1) When calculating voltage between two points without a direct connection, you can use any closed path (KVL loop) that contains both points — the result will be the same regardless of the path chosen, which serves as a verification method. (2) Voltage polarity matters: V_db = -V_bd, so always pay attention to the order of subscripts and the direction of traversal. (3) In mesh analysis with current sources, the current source directly determines the mesh current in that mesh (if it's on the outer edge) or creates a constraint between meshes. (4) The voltage across a shared resistor between two meshes is R times the difference of the mesh currents. (5) Always verify your results by using at least two different paths or methods — if they agree, your answer is likely correct.
🧠 Quick Revision Questions
- In the first example, what two different paths were used to verify V_ac = 10 volts?
- Why does V_db equal -V_bd, and what does this tell us about voltage polarity conventions?
- In the third example, how did the 2mA current source determine I₂ directly, and what effect did this have on setting up the mesh equations?
- What formula is used to find the voltage across the 6kΩ resistor that is shared between meshes 1 and 2?
- Why did V₀ calculate to 0 volts in the third example, and what does this result tell us about the circuit's behavior?
📘 Lecture 16 — Applications of Loop Analysis
📖 Overview: This lecture demonstrates practical applications of Kirchhoff's Voltage Law (KVL) and loop analysis to solve for unknown voltages and currents in various circuit configurations. Through multiple worked examples, students learn how to set up mesh equations, handle current sources within meshes, and compute specific circuit parameters like voltage across components and branch currents.
🗂️ Topics Covered
The lecture covers six complete examples applying loop analysis techniques. The first example calculates voltage across specific nodes using a single loop circuit. The second example finds voltage between two nodes by first computing voltage across a resistor. The third example calculates current through a shared branch in a two-mesh circuit with a known current source. The fourth example solves for both unknown current and voltage in a two-mesh configuration. The final two examples demonstrate loop analysis in circuits containing independent current sources, showing how to handle mesh currents that are directly determined by source values.
📝 Lecture Summary
Example: Calculate the voltage Vac
We want to calculate the voltage across nodes a and c. To solve this problem, the circuit is first redrawn to clearly show the loop.
Let the current I₁ flow through the circuit. Applying KVL: 10kI₁ + 20kI₁ + 30kI₁ - 6 = 0 10kI₁ + 20kI₁ + 30kI₁ = 6 60kI₁ = 6 I₁ = 6/60k I₁ = 0.1mA
Now Vac will be equal to the voltage across the 10kΩ and 20kΩ resistors combined: Vac = (10k + 20k)I₁ Vac = 30k(0.1mA) Vac = 3 Volts
Example: Calculate the voltage Vbd
We want to calculate the voltage between nodes b and d. First, we calculate the voltage across the 40kΩ resistor.
Applying KVL to the single loop: 10kI₁ + 9 + 40kI₁ + 10kI₁ - 6 = 0 60kI₁ = -3 I₁ = -3/60k I₁ = -0.05 mA
So, voltage across the 40kΩ resistor: V₄₀ₖ = (-0.05m)(40k) V₄₀ₖ = -2 volts — (A)
To calculate Vbd, we redraw the circuit and take the path b-d-c-b. Applying KVL along this path: Vbd - V₄₀ₖ - 9 = 0 Substituting the value of V₄₀ₖ from equation (A): Vbd - (-2) - 9 = 0 Vbd + 2 - 9 = 0 Vbd = 7 Volts
Example: Calculate the current I₀
We want to calculate the current through the 4kΩ resistor (I₀). The circuit is redrawn to identify two meshes.
For Mesh 1: I₁ = 120 mA (determined by the current source)
Applying KVL to Mesh 2: 8kI₂ + 4kI₂ + 4k(I₂ - I₁) = 0 16kI₂ - 4kI₁ = 0 16kI₂ - 4k(120m) = 0 16kI₂ = 480 I₂ = 480/16k I₂ = 30 mA
So I₀ will be the current through the 4kΩ resistor shared by both meshes: I₀ = I₁ - I₂ I₀ = 120 - 30 I₀ = 90 mA
Example: Calculate the current I₀ and the voltage V₀
We want to calculate both the unknown current and voltage. The circuit is redrawn to show two meshes.
Applying KVL to Mesh 1: 2kI₁ + 6k(I₁ - I₂) = 12 8kI₁ - 6kI₂ = 12 — (Equation 1)
Applying KVL to Mesh 2: 8kI₂ + 4kI₂ + 6k(I₂ - I₁) = 0 18kI₂ - 6kI₁ = 0 — (Equation 2)
Solving equations of mesh 1 and mesh 2 by multiplying Equation 1 by 3: 24kI₁ - 18kI₂ = 36 — (Equation 1 × 3) -24kI₁ + 72kI₂ = 0 — (Equation 2 × 4) Adding: 54kI₂ = 36 I₂ = 36/54k I₂ = 0.67mA — (A)
Now V₀ will be equal to the voltage across the 4kΩ resistor: V₀ = 4k × I₂ Substituting the value of I₂ from equation (A): V₀ = 4k × 0.67m V₀ = 2.66 Volts
Example: Calculate the current I₀
We want to calculate the current I₀. The circuit contains two independent current sources.
Here: I₁ = -2 mA (negative because the assumed direction of I₁ is opposite to the independent current source direction) I₃ = 4 mA (determined by the current source)
Applying KVL to Mesh 2: 4kI₂ + 6k(I₂ - I₃) + 2k(I₂ - I₁) = 12 4kI₂ + 6kI₂ - 6k(4m) + 2kI₂ - 2k(-2m) = 12 12kI₂ - 24 + 4 = 12 12kI₂ - 20 = 12 12kI₂ = 32 I₂ = 32/12k I₂ = 8/3 mA I₂ = 2.66 mA
I₀ is the same as mesh current I₂: I₀ = 2.66 mA
🔑 Definition — Mesh current: The current that flows around a complete loop (mesh) in a circuit, used as the variable in loop analysis.
Example: Calculate the current I₀
We want to calculate the current I₀ in this circuit configuration. The circuit is redrawn to identify three meshes.
Here: I₁ = -2 mA (opposite direction to current source) I₃ = 4 mA (determined by current source)
Applying KVL to Mesh 2: 2kI₂ + 1k(I₂ - I₁) = 12 2kI₂ + 1kI₂ - 1k(-2m) = 12 3kI₂ + 2 = 12 3kI₂ = 10 I₂ = 10/3 mA I₂ = 3.33 mA
I₀ is the current through the shared branch between meshes 1 and 2: I₀ = I₁ - I₂ I₀ = -2 - 3.33 I₀ = -5.33 mA
💡 Why this matters: The negative sign indicates that the actual direction of I₀ is opposite to the assumed direction. The magnitude tells us the current value, while the sign tells us the direction.
⭐ Key Takeaways
When using loop analysis with independent current sources, mesh currents may be directly determined by these sources, significantly simplifying the problem by reducing the number of unknown variables. Remember that when a current source is shared between two meshes, you must account for the current flow direction carefully — a negative mesh current simply means the actual current flows opposite to your assumed direction. For multi-mesh circuits, always set up KVL equations systematically, paying special attention to voltage drops across resistors shared by adjacent meshes (these involve current differences). When calculating voltage between two nodes, you can take any convenient path between those nodes and apply KVL, as long as all component voltages along that path are known. Finally, in single-loop circuits, once you find the loop current, you can directly compute any voltage using Ohm's law across the relevant resistors.
🧠 Quick Revision Questions
-
In the voltage Vbd example, why did the voltage across the 40kΩ resistor come out negative, and how did this affect the final calculation of Vbd?
-
When a mesh contains an independent current source, how do you determine that mesh current, and what special consideration is needed for the direction?
-
In the last example, why was I₀ calculated as I₁ - I₂ rather than I₂ - I₁, and what does the negative result tell you?
-
For the example calculating both I₀ and V₀, explain the steps to solve the two simultaneous equations derived from KVL.
-
In the current I₀ example with 120mA source, how was the current through the 4kΩ resistor determined from the two mesh currents?
📘 Lecture 17 — Applications of Loop Analysis
📖 Overview: This lecture demonstrates the practical application of mesh (loop) analysis to solve circuits containing dependent sources and multiple meshes. Through three detailed examples, students learn how to set up and solve mesh equations systematically to find unknown voltages and currents.
🗂️ Topics Covered
Three example problems are solved in detail: the first example calculates voltage V₀ using two mesh equations solved simultaneously, the second example involves a dependent source requiring substitution of the controlling variable, and the third example features a dependent voltage source where mesh currents simplify significantly. Each example reinforces the mesh analysis methodology.
📝 Lecture Summary
Example: Calculate the voltage V₀
The circuit has three meshes. Mesh 1 has a known current source of 2mA directly assigned. For mesh 2, the KVL equation includes the 6V source and resistors 4kΩ and 2kΩ: 4k(I₂ – I₃) + 2k(I₂ – I₁) = 6. With I₁ = 2mA, this simplifies to 6kI₂ – 4kI₃ = 10.
For mesh 3, all resistors (6kΩ, 2kΩ, and 4kΩ) contribute: 6kI₃ + 2k(I₃ – I₁) + 4k(I₃ – I₂) = 0. Substituting I₁ = 2mA gives 12kI₃ – 4kI₂ = 4.
Solving the two equations simultaneously: multiply the mesh 2 equation by 4 and mesh 3 equation by 6, then subtract to eliminate I₂. This yields 56kI₃ = 64, so I₃ = 1.142mA.
The output voltage V₀ is across the 6kΩ resistor: V₀ = 6k × I₃ = 6k × 1.142mA.
📌 Example: V₀ = 6.85 volts
Example: Calculate the voltage V₀
This circuit contains a dependent voltage source (4Va) in mesh 2. The circuit is redrawn to identify meshes clearly. For mesh 1: Va + 4k(I₁ – I₂) = 12. For mesh 2: 4Va + 6kI₂ + 4k(I₂ – I₁) = 0.
The controlling variable Va is the voltage across the 2kΩ resistor in mesh 1: Va = 2kI₁.
Substituting Va = 2kI₁ into the mesh 1 equation: 2kI₁ + 4kI₁ – 4kI₂ = 12 → 6kI₁ – 4kI₂ = 12. Substituting into mesh 2: 8kI₁ + 10kI₂ – 4kI₁ = 0 → 4kI₁ + 10kI₂ = 0.
Solving: multiply the first equation by 1.5 → 9kI₁ – 6kI₂ = 18. Subtract the second equation (4kI₁ + 10kI₂ = 0) from this. The system is solved by elimination: from 4kI₁ + 10kI₂ = 0, I₁ = -2.5I₂. Substituting into 6k(-2.5I₂) – 4kI₂ = 12 gives -19kI₂ = 12.
🔑 Definition — I₂: I₂ = -12/19 mA = -0.6315mA
The output voltage V₀ is across the 6kΩ resistor: V₀ = 6k × I₂ = 6k × 0.6315mA.
📌 Example: V₀ = 3.78 volts
💡 Why this matters: When dependent sources appear, the controlling variable must be expressed in terms of mesh currents and substituted into the equations — this creates a system that can still be solved with standard linear algebra.
Example: Calculate the voltage V₀
This circuit has a dependent voltage source (2kIₓ) in series with a 2kΩ resistor. The circuit is redrawn to show two meshes. For mesh 1: 2kI₁ + 4k(I₁ – Iₓ) – 2kIₓ = 0. Note the dependent source subtracts because of polarity.
Simplifying mesh 1: 6kI₁ – 4kIₓ – 2kIₓ = 0 → 6kI₁ – 6kIₓ = 0 → I₁ = Iₓ.
For mesh 2: 2kIₓ + 4k(Iₓ – I₁) – 6 = 0. Since I₁ = Iₓ, this simplifies to 2kIₓ + 4k(Iₓ – Iₓ) – 6 = 0 → 2kIₓ – 6 = 0.
Solving: 2kIₓ = 6 → Iₓ = 3mA.
The output voltage V₀ is across the 2kΩ resistor in mesh 2: V₀ = 2k × Iₓ = 2k × 3mA.
📌 Example: V₀ = 6 Volts
💡 Why this matters: When dependent sources cause mesh currents to become equal, the circuit simplifies dramatically — always check for such relationships before solving the full system.
⭐ Key Takeaways
Mesh (loop) analysis is a systematic method for solving circuits with multiple loops. When a current source is present in a mesh, its value can be directly assigned as the mesh current. For dependent sources, the controlling variable must be expressed in terms of mesh currents and substituted into the KVL equations. Solving two simultaneous equations can be done by elimination or substitution. The output voltage is always found by multiplying the appropriate mesh current by the resistance across which it is measured. Always verify current directions and source polarities before writing KVL equations.
🧠 Quick Revision Questions
- In the first example, why was I₁ directly set to 2mA without writing a KVL equation for mesh 1?
- In the second example, how was the dependent source voltage 4Va expressed in terms of mesh currents?
- In the third example, what relationship between I₁ and Iₓ simplified the circuit solution?
- What is the general procedure when a dependent source appears in a mesh analysis problem?
- If the mesh equations 6kI₁ – 4kI₂ = 12 and 4kI₁ + 10kI₂ = 0 are given, solve for I₂ using elimination.
📘 Lecture 18 — Applications of Loop Analysis-Super Mesh Technique
📖 Overview: This lecture focuses on applying loop analysis and the super mesh technique to solve complex circuits. It demonstrates how to handle circuits with dependent sources, current sources, and multiple meshes, showing that loop analysis often simplifies calculations compared to nodal analysis.
🗂️ Topics Covered
The lecture covers five detailed examples demonstrating loop analysis and super mesh technique applications. Examples include calculating voltage across resistors using mesh currents with dependent sources, solving circuits with voltage-controlled voltage sources, handling circuits with multiple current sources using super mesh approach, and determining currents through specific branches using simplified mesh analysis.
📝 Lecture Summary
Example: Calculate the voltage V₀
The circuit contains a dependent voltage source Vx and requires solving for output voltage V₀ across a 6kΩ resistor.
First, the circuit is redrawn to identify three meshes. The relationships between mesh currents are established using the dependent source constraints.
🔑 Definition — Vx: The voltage across the 6kΩ resistor between meshes 2 and 3, given by Vx = (I₂ - I₃)6kΩ.
From the dependent source connection: I₁ = Vx/2kΩ. Substituting Vx gives I₁ = 3(I₂ - I₃).
Given that I₂ = 2mA, this simplifies to I₁ = 6mA - 3I₃.
📐 Formula — KVL for Mesh 3: 6kΩ I₃ + 6kΩ(I₃ - I₂) + 2kΩ(I₃ - I₁) = 0
Substituting values: 6kI₃ + 6kI₃ - 12 + 2kI₃ - 2k(6mA - 3I₃) = 0
Simplifying: 14kI₃ - 12 - 12 + 6kI₃ = 0 → 20kI₃ = 24
📌 Example: I₃ = 24/20k = 1.2mA, therefore V₀ = 6kΩ × 1.2mA = 7.2 volts
Example: Calculate the voltage Vₐ
This circuit contains a voltage-controlled voltage source 2Vₐ. The problem notes that while super node technique could solve this, loop analysis is more efficient.
The circuit has four meshes with I₄ = 1A given directly.
For mesh 1: 1Ω(I₁ - I₂) + 3Ω(I₁ - I₃) - 5 = 0 → 4I₁ - 3I₃ - I₂ = 5 ... Equation (A)
For mesh 2: 2I₂ + 3I₂ - 2Vₐ + I₂ - I₁ = 0 → 6I₂ - I₁ = 2Vₐ ... Equation (B)
🔑 Definition — Vₐ: The voltage across the 3Ω resistor in mesh 2, given by Vₐ = 3I₂
Substituting Vₐ into equation (B): 6I₂ - I₁ = 2(3I₂) → I₁ = 0
For mesh 3: 2Vₐ + 5(I₃ - I₄) + 3(I₃ - I₁) = 0
Substituting I₁ = 0, I₄ = 1A, and Vₐ = 3I₂: 6I₂ + 3I₃ + 5I₃ - 5 = 0 → 8I₃ + 6I₂ = 5
Solving equations (A) and mesh 3 equation simultaneously:
- From (A) with I₁ = 0: -3I₃ - I₂ = 5 → multiply by 6: -18I₃ - 6I₂ = 30
- From mesh 3: 8I₃ + 6I₂ = 5
Adding: -10I₃ = 35 → I₃ = -3.5A
📌 Example: Substituting I₃ into equation (A): 10.5 - I₂ = 5 → I₂ = 5.5A
Therefore Vₐ = 3 × 5.5 = 16.5 volts
Example: Find Current through all meshes
This example demonstrates the super mesh technique for a circuit containing a current source between two meshes.
The instructor first shows an incorrect approach and then the correct super mesh method.
The circuit has four meshes with the following known currents from current sources: I₂ = -5A and I₃ = +5A.
🔑 Definition — Super Mesh: When a current source exists between two meshes, we combine those meshes into a single "super mesh" and apply KVL around the combined loop, while using the current source to relate the mesh currents.
KVL for mesh 1: -5 + I₁ - I₃ + 2I₁ = 0 ... Equation (1)
KVL for super mesh (combining meshes 2, 3, and 4): 1Ω(I₃ - I₁) + 4Ω I₂ + 3Ω I₂ + 2 + 4Ω I₃ - 4Ω I₄ + 6Ω I₃ = 0 ... Equation (2)
KVL for mesh 4: 4Ω I₄ - 4Ω I₃ + 2Ω I₄ - 3 = 0 ... Equation (3)
Simplifying:
- Equation (1): 3I₁ - I₃ = 5
- Equation (2): -I₁ + 7I₂ + 11I₃ - 4I₄ = -2
- Equation (3): -4I₃ + 6I₄ = 3
- From current source: -I₂ + I₃ = 5
📌 Example: Solving the system yields: I₁ = 2.481A, I₂ = -2.556A, I₃ = 2.444A, I₄ = 2.130A
Example: Calculate current I₀
The circuit contains two current sources that directly set two mesh currents. This simplifies the analysis significantly.
I₁ = -1mA and I₂ = -2mA are given directly from the current sources.
KVL for loop 3: 1kΩ(I₃ + I₁) + 2kΩ I₃ + 1kΩ(I₃ + I₂) = 2 + 4
Expanding: 1kI₃ + 1kI₁ + 2kI₃ + 1kI₃ + 1kI₂ = 6
Simplifying: 4kI₃ - 1 - 2 = 6 → 4kI₃ - 3 = 6 → 4kI₃ = 9
📌 Example: I₃ = 9/4 mA = 2.25mA. Since I₀ = I₃, the answer is I₀ = 2.25mA
Example: Calculate current I₀
Similar to the previous example, current sources directly define two mesh currents.
I₁ = 2mA and I₂ = -4mA from the current sources.
KVL for loop 3: 2kΩ I₃ + 2kΩ(I₃ + I₂) = 12
Expanding: 2kI₃ + 2kI₃ + 2kI₂ = 12 → 4kI₃ - 8 = 12 → 4kI₃ = 20
📌 Example: I₃ = 5mA. Note that I₀ = I₃ + I₁ = 5mA + 2mA = 7mA
💡 Why this matters: This example shows that the desired current may be a combination of mesh currents, not just a single mesh current.
⭐ Key Takeaways
The super mesh technique is essential when a current source lies between two meshes, as it allows us to create a combined loop for KVL while using the current source relation between meshes. Dependent sources require expressing the controlling variable in terms of mesh currents before solving the system of equations. Loop analysis often simplifies circuits with many voltage sources compared to nodal analysis, especially when current sources directly define some mesh currents. When writing mesh equations, pay careful attention to the sign conventions and ensure all terms are collected properly. The desired output current or voltage may be a combination of multiple mesh currents, not simply one mesh current.
🧠 Quick Revision Questions
- How do you handle a current source that exists between two meshes in loop analysis?
- In the Vₐ example, why did I₁ become zero, and how did this simplify the solution?
- What is the relationship between I₁ and the dependent source Vx in the first example?
- In the last example, why was I₀ equal to I₃ + I₁ instead of just I₃?
- When using the super mesh technique, how many KVL equations do you write for the combined super mesh?
📘 Lecture 19 — (Examples of Loop Analysis)
📖 Overview: This lecture demonstrates the practical application of loop analysis (mesh analysis) to solve for unknown currents and voltages in circuits containing multiple current sources. It shows how to systematically assign loop currents, apply Kirchhoff’s Voltage Law (KVL), and solve simultaneous equations to find the desired quantities, reinforcing the method through three worked examples.
🗂️ Topics Covered
This lecture covers three detailed examples of loop analysis. The first example calculates the current (I_o) in a circuit with three loops and two independent current sources. The second example calculates the voltage (V_o) across a resistor in a four-loop circuit. The third example calculates the voltage (V_o) in a more complex four-loop circuit with three current sources. Each example demonstrates the step-by-step process of redrawing the circuit, identifying known mesh currents from current sources, applying KVL to the unknown loop, and solving for the required value.
📝 Lecture Summary
Example: Calculate the current (I_o).
The objective is to find the current (I_o) through a specific branch. The circuit is redrawn to clearly define loop currents. In this configuration, two current sources directly determine two loop currents: (I_1 = 2,mA) and (I_2 = -4,mA). The negative sign indicates the direction of the source is opposite to the assumed loop current direction.
The Kirchhoff’s Voltage Law (KVL) equation is written for the third loop (loop 3), which does not have a current source. The sum of voltage drops around loop 3 is set equal to the voltage source (+12V). The equation is: [ 2k\Omega I_3 + 1k\Omega (I_3 - I_2) + 2k\Omega (I_3 + I_1 - I_2) = 12V ]
🔑 Definition — Loop Analysis: A method that uses loop (mesh) currents as unknowns and applies KVL to each independent loop to form a set of simultaneous equations.
📐 Formula: The KVL equation for loop 3 is simplified by combining like terms: (5k\Omega I_3 - 3k\Omega I_2 + 2k\Omega I_1 = 12V)
📌 Example: Substitute (I_1 = 2,mA) and (I_2 = -4,mA) into the simplified equation: (5k\Omega I_3 - 3k\Omega(-4m) + 2k\Omega(2m) = 12V) → (5k\Omega I_3 + 12 + 4 = 12) → (5k\Omega I_3 = -4) → (I_3 = -0.8,mA) The required current (I_o) is the sum of loop currents flowing through the output branch: (I_o = I_3 + I_1 - I_2 = -0.8 + 2 - (-4)) → (I_o = 5.2,mA).
💡 Why this matters: This example shows how to handle independent current sources in loop analysis. They directly set the loop current, simplifying the system of equations.
Example: Calculate the voltage (V_o).
The goal is to find the voltage (V_o) across a 1k(\Omega) resistor. The circuit is redrawn to show four clear loop currents. Three current sources define the first three loop currents directly: (I_1 = -2,mA), (I_2 = -4,mA), and (I_3 = 4,mA).
KVL is applied to loop 4, which does not contain a current source. The sum of voltage drops across the resistors in loop 4 equals zero (no voltage source in this loop). The equation is: [ 1k\Omega (I_4 - I_1) + 1k\Omega (I_4 - I_2) + 1k\Omega I_3 + 2k\Omega I_4 = 0 ]
🔑 Definition — Voltage across a resistor: Given by Ohm’s Law, (V = IR), where (I) is the net current flowing through the resistor.
📐 Formula: Simplifying the KVL equation for loop 4: (4k\Omega I_4 + 1k\Omega I_3 - 1k\Omega I_1 - 1k\Omega I_2 = 0)
📌 Example: Substitute the known currents: (4k\Omega I_4 + 1k(4m) - 1k(-2m) - 1k(-4m) = 0) → (4k\Omega I_4 + 4 + 2 + 4 = 0) → (4k\Omega I_4 = -10) → (I_4 = -2.5,mA). The current through the 1k(\Omega) resistor where (V_o) is measured is (I_{1k} = I_4 - I_1 = -2.5 - (-2) = -0.5,mA). Therefore, (V_o = 1k\Omega \times 0.5,mA = 0.5,V). Note: The magnitude is used for the voltage value.
💡 Why this matters: This example demonstrates how to calculate a specific voltage by first finding its branch current using loop analysis, and then applying Ohm's Law.
Example: Calculate the voltage (V_o).
The circuit is redrawn to identify loop currents. Three current sources directly set three loop currents: (I_1 = 4,mA), (I_2 = -2,mA), and (I_3 = 1,mA).
KVL is applied to loop 4. The resistors in this loop have voltages that sum to zero (no independent voltage source). The equation is: [ 1k\Omega (I_4 - I_1) + 1k\Omega (I_4 - I_2 + I_3) + 2k\Omega (I_4 + I_3) + 1k\Omega I_4 = 0 ]
🔑 Definition — Supermesh: When a current source is common to two loops, a supermesh is formed by combining the two loops and applying KVL. This example uses the standard approach where the source sets one current.
📐 Formula: Simplifying the KVL equation for loop 4: (5k\Omega I_4 - 1k\Omega I_1 - 1k\Omega I_2 + 1k\Omega I_3 + 2k\Omega I_3 = 0) → (5k\Omega I_4 - 4V + 2V + 1V + 2V = 0)
📌 Example: Substitute known values: (5k\Omega I_4 - 4 + 2 + 1 + 2 = 0) → (5k\Omega I_4 = -1) → (I_4 = -0.2,mA). The voltage (V_o) is across the 2k(\Omega) resistor, and the net current through it is (I_4 + I_3). So, (V_o = 2k\Omega , (I_4 + I_3) = 2k\Omega (-0.2m + 1m)) → (V_o = 2k\Omega \times 0.8,mA = 1.6,V).
💡 Why this matters: This example illustrates how loop currents can be combined to find the net current through a specific component for voltage calculation.
⭐ Key Takeaways
The core skill reinforced in this lecture is the systematic application of loop analysis to circuits with multiple current sources. First, identify all independent loops. Second, note that a current source that is alone in a loop directly determines that loop's current, often with a sign change. Third, for loops without a source, write a KVL equation summing all voltage drops to zero or the source voltage. Fourth, carefully account for all current contributions from neighboring loops when writing the voltage drop across a shared resistor. Finally, to find a specific branch current or voltage, combine the relevant loop currents with proper signs and apply Ohm’s Law.
🧠 Quick Revision Questions
- In loop analysis, what is the first step when a current source is present in a single loop?
- In Example 1, why is the equation (I_o = I_3 + I_1 - I_2) used to find the final current?
- In Example 2, what is the value of (V_o) and how is it calculated after finding (I_4) and (I_1)?
- In Example 3, why is the current through the 2k(\Omega) resistor (I_4 + I_3) and not just (I_4)?
- State the general rule for determining the sign of a loop current when a current source points opposite to the assumed loop direction.
📘 Lecture 20 — (Super Mesh Technique - Coupling equation)
📖 Overview: This lecture introduces the super mesh technique, a powerful method for analyzing circuits that contain current sources shared between two meshes. It also covers the coupling equation used to relate mesh currents when dependent sources are present. Multiple worked examples demonstrate how to apply these techniques to find unknown voltages and currents.
🗂️ Topics Covered
The lecture covers several complete circuit analysis examples using mesh analysis. It demonstrates how to handle circuits with independent current sources (using super mesh when sources are common to two meshes) and dependent sources (using coupling equations). Each example shows the step-by-step process of setting up and solving simultaneous equations to find unknown voltages and currents.
📝 Lecture Summary
Example: Calculate the voltage Vo
We want to calculate the voltage V₀. The circuit is redrawn with mesh currents labeled. It contains a 2mA current source that establishes I₁.
Here, I₁ = -2mA (the negative sign indicates the assumed direction is opposite to the source's actual direction).
KVL equation for loop 2: 2kΩ·I₂ + 4kΩ·I₂ + 2kΩ·(I₂ + I₁) = 12 6kΩ·I₂ + 2kΩ·I₂ + 2kΩ·I₁ = 12 8kΩ·I₂ – 4 = 12 8kΩ·I₂ = 16 I₂ = 2mA
V₀ = 2kΩ·(I₂) = 2kΩ·(2mA) = 4 volts
📌 Example: This example shows a simple two-mesh circuit where one current is set by a source. Finding I₂ allows direct calculation of output voltage V₀.
Example: Calculate the voltage Vo
We want to find the voltage V₀. The circuit is redrawn with mesh currents. It contains two independent current sources that set I₁ and I₂.
Here: I₁ = 3mA I₂ = 1mA
KVL for loop 3: 4kΩ·I₃ + 2kΩ·(I₃ + I₂) + 4kΩ·(I₃ – I₁) + 2kΩ·(I₃ – I₁) = 6 4kΩ·I₃ + 2kΩ·I₃ + 2kΩ·I₂ + 4kΩ·I₃ – 4kΩ·I₁ + 2kΩ·I₃ – 2kΩ·I₁ = 6 12kΩ·I₃ + 2 – 12 – 6 = 12 12kΩ·I₃ = 22 I₃ = 11/6 mA = 1.833mA
V₀ = 4kΩ·I₃ = 4kΩ·1.833mA = 7.33 volts
📌 Example: With two currents set by sources, only one unknown mesh current remains. Solving the single KVL equation gives V₀.
Example: Calculate the current Io
We want to find the current I₀. The circuit is redrawn with mesh currents. It contains two independent current sources and requires solving a system of simultaneous equations.
Here: I₁ = -2mA I₃ = 1mA
KVL for mesh 2: 4kΩ·(I₂ + I₄) + 2kΩ·(I₂ – I₃) + 2kΩ·(I₂ – I₁) = 0 8kΩ·I₂ + 4kΩ·I₄ – 2 + 4 = 0 4kΩ·I₂ + 2kΩ·I₄ = -1
KVL for loop 4: 4kΩ·(I₄ + I₂) + 2kΩ·(I₄ + I₃) + 6kΩ·I₄ – 6 = 0 12kΩ·I₄ + 4kΩ·I₂ + 2 – 6 = 0 12kΩ·I₄ + 4kΩ·I₂ – 4 = 0 3kΩ·I₄ + 1kΩ·I₂ = 1
Multiplying the mesh 2 equation by 3 and the loop 4 equation by 2, then subtracting: 12kΩ·I₂ + 6kΩ·I₄ = -3 -2kΩ·I₂ – 6kΩ·I₄ = -2 10kΩ·I₂ = -5 I₂ = -0.5mA
I₀ = I₁ – I₂ = -2mA – (-0.5mA) = -1.5mA
📌 Example: When two unknowns remain (I₂ and I₄), two simultaneous equations are needed. The solution requires algebraic manipulation to eliminate one variable.
Example: Find the currents I₁, I₂ and I₃
We want to find currents I₁, I₂, and I₃. The circuit contains a dependent voltage source, requiring a super mesh and a coupling equation.
The circuit is redrawn. For mesh 1: 4I₁ - 4I₂ + 1 = 0 ... equation (1)
For the super mesh (mesh 2 and mesh 3 combined): 3I₂ + 2I₃ + 4I₂ - 4I₁ = 0 ... equation (2)
Coupling Equation: I₃ – I₂ = 2Vx
Here, Vx = 3I₂, so: I₃ – I₂ = 2(3I₂) = 6I₂ I₃ – I₂ = 6I₂ -7I₂ + I₃ = 0 ... equation (3)
Solving equation (1): 4I₁ – 4I₂ = -1
Solving equation (2): -4I₁ + 7I₂ + 2I₃ = -1
Solving equations (1), (2), and (3): I₁ = -308.8 mA I₂ = -58.82 mA I₃ = -411.8 mA
🔑 Definition — Super Mesh: When a current source (independent or dependent) is present between two meshes, a "super mesh" is formed by combining those two meshes into one larger loop, excluding the current source and any elements in series with it.
🔑 Definition — Coupling Equation: An additional equation derived from the relationship between the current source (especially dependent sources) and the mesh currents, used alongside super mesh analysis to solve for unknown currents.
💡 Why this matters: Circuits with dependent sources cannot be solved using standard mesh analysis alone. The super mesh technique combined with coupling equations provides the complete set of equations needed for analysis.
⭐ Key Takeaways
The super mesh technique is essential when a current source is shared between two meshes — the two meshes are combined into one larger loop for KVL, while the coupling equation from the current source provides the missing relationship between mesh currents. For dependent sources, the coupling equation expresses the controlling variable in terms of mesh currents. Multiple examples demonstrate that systematic equation setup and simultaneous solving yields all unknown mesh currents, from which branch currents and voltages can be calculated. The sign convention must be carefully maintained throughout, and current sources directly set their respective mesh currents when they appear in only one mesh.
🧠 Quick Revision Questions
- When must a super mesh be used instead of regular mesh analysis?
- What is a coupling equation, and how is it derived for a dependent voltage source?
- In the first example, why is I₁ negative (-2mA) rather than positive?
- How do you handle a circuit with two independent current sources and two remaining unknown mesh currents?
- What algebraic technique was used to solve the system of two equations in the I₀ example?